Seven-axis adaptive arm with whole-body force sensing. This record covers Rizon 10 without the optional flange force/torque sensor.
- Form
- arm
- Purpose
- Force-controlled automation
Specifications
Manufacturer-reported hardware and purchase details. Configuration differences stay with each value.
| Attribute | Reported value | Source |
|---|---|---|
| Configuration | ||
| Axes | 7 | 2026-10-26 |
| Mounting | Any orientation | 2026-10-26 |
| Tool flange | ISO 9409-1-50-4-M6 | 2026-10-26 |
| Environment | ||
| Humidity | 20–80%, non-condensing | 2026-10-26 |
| Temperature | 0–45°C | 2026-10-26 |
| Manipulation | ||
| Maximum TCP force | 350 N | 2026-10-26 |
| Payload | 10 kg | 2026-10-26 |
| Pose repeatability | ±0.05 mm, ISO 9283 | 2026-10-26 |
| Reach | 941 mm | 2026-10-26 |
| Typical TCP linear speed | 1.0 m/s | 2026-10-26 |
| Physical | ||
| Arm mass | 38 kg | 2026-10-26 |
| Protection | ||
| Ingress rating | IP65 | 2026-10-26 |
| Purchase | ||
| Availability and region | Official sales enquiry route; confirm regional supply, tooling, installation and lead time. | 2026-10-26 |
| Pricing basis | Manufacturer sales quote; end effector, integration and regional terms are configuration-dependent. No public configured USD price verified. | 2026-10-26 |
| Sensors | ||
| Force sensing accuracy | 0.2 N; current standard Rizon 10 product table | 2026-10-26 |
Evidence map
1 of 25 measurements have records. Each column shows a kind of evidence, not a performance rating. Select a count to read the records.
| Measurement | Manufacturer reported | Demonstrated | Community tested | Independently benchmarked |
|---|---|---|---|---|
| Autonomy | ||||
| Autonomous completion | No records | No records | No records | No records |
| Failure recovery | No records | No records | No records | No records |
| Intervention burden | No records | No records | No records | No records |
| Intervention frequency | No records | No records | No records | No records |
| Novelty degradation | No records | No records | No records | No records |
| Endurance & reliability | ||||
| Charging time | No records | No records | No records | No records |
| Energy per task | No records | No records | No records | No records |
| Mission failure rate | No records | No records | No records | No records |
| Working runtime | No records | No records | No records | No records |
| Interaction | ||||
| Human setup time | No records | No records | No records | No records |
| Instruction following | No records | No records | No records | No records |
| Response latency | No records | No records | No records | No records |
| Manipulation | ||||
| Door opening | No records | No records | No records | No records |
| Fine manipulation | 1 | No records | No records | No records |
| Multistep execution | No records | No records | No records | No records |
| Object retrieval | No records | No records | No records | No records |
| Unfamiliar-object grasping | No records | No records | No records | No records |
| Mobility | ||||
| Load carrying | No records | No records | No records | No records |
| Obstacle avoidance | No records | No records | No records | No records |
| Room navigation | No records | No records | No records | No records |
| Stair climbing | No records | No records | No records | No records |
| Travel speed | No records | No records | No records | No records |
| Ownership | ||||
| Cost per successful task | No records | No records | No records | No records |
| Operating cost | No records | No records | No records | No records |
| Purchase cost | No records | No records | No records | No records |
— No records: not assessed, not zero performance. Some measurements may not apply to this form factor. Counts indicate documentation, not quality or independent verification.
Evidence records
Claims stay attributed. Read each record for hardware, conditions, limitations and disclosures.
1 of 1 records
| Record / measurement | Attribution / context | Result | Record date |
|---|---|---|---|
Fine manipulation Fine manipulation · manufacturer claimFlexiv reports ±0.05 mm pose repeatability and 0.2 N force-sensing accuracy for the standard Rizon 10 configuration. | Manufacturer reported Omblet editorial Environment unspecified | No measured value | 2026-10-26 |
In the hands of owners
Public robot profiles, configurations and experience from the people using this model.